The FLIR E75 has the sensitivity and resolution needed to diagnose problems and find hidden deficiencies, even from a distance. The 320 x 240 true native resolution offers more than 76,000 points of temperature measurement and produces crisp, vibrant imagery, while interchangeable lenses offer complete coverage of near and distant targets.
The screening alarm can be used, for example, at airports to detect passengers with elevated body temperatures, which may indicate the presence of a fever.
The screening alarm can also be used to detect temperature anomalies in a series of inspected objects in a similar/fixed setup.
Activating the screening mode will turn on a measurement box and screening data in the result table.
1) The sampled average temperature.
2) The alarm temperature.
3) The measured temperature.
The alarm will trigger when the measurement box measures a temperature higher than the alarm temperature. The alarm temperature is, in turn, the sum of a specified allowed deviation and a sampled average value.
OVERVIEW
Accuracy
±2°C (±3.6°F) or ±2% of reading for ambient temperature 15°C to 35°C (59°F to 95°F) and object temperature above 0°C (32°F)
•ETSI EN 300 328 •FCC Part 15.249 •RSS-247 Issue 2
Safety
EN/UL/CSA/PSE 60950-1
Storage Temperature Range
–40°C to 70°C (-40°F to 158°F)
Tripod Mounting
UNC 1/4''–20
Shock & Vibration & Encapsulation
25 g / IEC 60068-2-27, 2 g / IEC 60068-2-6, IP 54 /IEC 60529; EN/UL/CSA/PSE 60950-1
IMAGING & OPTICAL
Additional lenses
•42°
Aspect ratio
4:3
Auto Rotation
Yes
Camera software update
Use PC software FLIR Tools
Color
Black
Color depth (bits)
24
Color palettes
Iron, Gray, Rainbow, Arctic, Lava, Rainbow HC
Detector Type and Pitch
Uncooled microbolometer, 17 µm
Digital Camera
5 MP, 53° x 41° FOV
Digital Zoom
1-4x continuous
f-number
•1.3, 24° •1.5, 14°
Field of view (FOV)
24° x 18° (17 mm lens), 14° x 10° (29 mm lens)
Field of view match
Yes
Focus
Continuous, one-shot laser distance meter (LDM), one-shot contrast, manual
Gallery
Yes
Image Adjustment
•Automatic •Automatic maximum •Automatic minimum •Manual
Image Frequency
30 Hz
Image Modes
Infrared, visual, MSX®, Picture-in-Picture
Image Sketch
Yes: on infrared images only
Infrared Image
Yes
Lens Identification
Automatic
Minimum Focus Distance
•0.15 m (0.49 ft.), 24° •1.0 m (3.28 ft.), 14°
Minimum Focus Distance with MSX
•0.5 m (1.64 ft.), 24° •1.0 m (3.28 ft.), 14°
Non-Radiometric IR or Visual Video
H.264 to memory card
Non-radiometric IR video streaming
H.264 or MPEG-4 over Wi-Fi MJPEG over UVC or Wi-Fi
Picture-in-Picture
Resizable and movable
Radiometric IR video recording
Real-time radiometric recording (.csq)
Radiometric IR video streaming
Over UVC
Spatial resolution (IFOV)
•1.09 mrad/pixel, 24° •0.63 mrad/pixel, 14°
Spectral Range
7.5 - 14.0 µm
Viewfinder
No
MSX
Embosses visual details on full resolution thermal image
Sketch
From touchscreen
UltraMax
Super-resolution process quadruples pixel count, activated in FLIR Tools+
Viewing Angle
80°
Visual Video Streaming
Yes
MEASUREMENT & ANALYSIS
Area
1 in live mode
Area measurement information
No
Measurement Corrections
Yes
Measurement Presets
No measurement, center spot, hot spot, cold spot, User Preset 1, User Preset 2
Reference Temperature
Yes
Spot Meter
3 in live mode
Laser Distance Measurement
Yes, on-screen
Automatic hot & cold detection
Auto-maximum/minimum markers within area
METER DATA
Display
4'', 640 x 480 optically-bonded PCAP touchscreen, with 400 cd/m2 surface brightness
POWER
Battery Life (Operating)
> 2.5 hours at 25°C (68°F) and typical use
Battery operating time
Approx. 2.5 hours at 25°C (77°F) ambient temperature and typical use
Battery size (L x W x H)
150 × 46 × 55 mm (5.9 × 1.8 × 2.2 in.)
Battery type
Li-ion battery, charged in camera or on separate charger
Battery voltage
3.6 V
Battery weight
140 g (4.9 oz.)
Charging Temperature
0°C to +45°C (+32°F to +113°F)
Charging Time (using two-bay charger)
2.5 hours to 90% capacity with charging status indicated by LEDs
External Power Operation
AC adapter 90–260 V AC, 50/60 Hz, or 12 V from a vehicle (cable with standard plug—optional)
Power Management
Automatic shut-down and sleep mode
SHIPPING INFORMATION
Packaging
Infrared camera with lens, battery (2 ea), battery charger with power supply, front lens and light protection, straps (hand and wrist), lanyards, lens caps (front and rear), lens cleaning cloth, 15 W3 A power supply, printed documentation, 8 GB SD card, Torx screwdriver, cables (USB 2.0 A to USB Type-C,USB Type-C to HDMI, USB Type-C to USB Type-C)
STORAGE MEDIA
Image File Format
Standard radiometric JPEG, measurement data included
The screening alarm can be used, for example, at airports to detect passengers with elevated body temperatures, which may indicate the presence of a fever.
The screening alarm can also be used to detect temperature anomalies in a series of inspected objects in a similar/fixed setup.
Activating the screening mode will turn on a measurement box and screening data in the result table.
1) The sampled average temperature.
2) The alarm temperature.
3) The measured temperature.
The alarm will trigger when the measurement box measures a temperature higher than the alarm temperature. The alarm temperature is, in turn, the sum of a specified allowed deviation and a sampled average value.